Country, region and language selection

International websites

Europe

Americas / Oceania

Africa and Middle East

Asia / Pacific

WKB Dry-installed pump

Dry-installed pump WKB

Vertically suspended, single-casing, lineshaft, diffuser-type pump with integral thrust bearings and discharge through column pipe in accordance with API 610 / ISO 13709 (VS1). Available in single-stage and multistage configurations and with either single or double suction first-stage impeller.
See all documents and downloads

Main Applications

  • Processes with critical NPSH conditions in chemical and petrochemical industries
  • Condensate transport
  • Pipelines and tank farms
  • Liquefied gas

Technical Data

Maximum flow rate TSG
350 m³/h
Maximum head TSG
500 m
Max allow ds work.pressure TSG
51 bar
Max allowed fluid temp TSG
250 °C

Your KSB contact: We’re here to support you

Do you need any assistance finding the right material number?
We’ll soon provide a list so you can directly place your purchase order.
Meanwhile please contact our support:

Your local contact


Your KSB contact : We’re here to support you

Benefits

  • Pump head is designed and welded according to ASME code to meet API nozzle load requirements. Suction areas designed for discharge pressure.
  • Circular or rectangular soleplate allows easy adaptation to different installation conditions.
  • Product-lubricated carbon guide bearings with bearing span below requirements of API 610 ensure low vibrations and reliable operation.

Technical Data

Component function
Pump
Connection type Inlet
Flange
Drive concept
With electric actuator
Maximum flow rate TSG
350 m³/h
Minimum flow rate TSG
0.1 m³/h
Maximum head TSG
500 m
Minimum head TSG
0.1 m
Mains frequency
50 Hz,
60 Hz
Mains voltage
110 V,
115 V,
120 V,
125 V,
200 V,
208 V,
220 V,
230 V,
240 V,
260 V,
276 V,
278 V,
380 V,
400 V,
415 V,
440 V,
460 V,
480 V,
500 V,
525 V,
575 V,
600 V,
660 V,
690 V,
760 V,
830 V,
1000 V,
3000 V,
4160 V,
5000 V,
5500 V,
6000 V,
6600 V,
6900 V,
11000 V
Mtrl Hydraulic casing
A516 GRADE 70,
SA240/SA240M TYPE 316L,
A240 TYPE 316,
A516 GRADE 60
Nominal pressure Outlet
CL 400,
PN 64
Max allow ds work.pressure TSG
51 bar
Suction behaviour
Non-self-priming
Max allowed fluid temp TSG
250 °C
Min allowed fluid temp TSG
-45 °C