Country, region and language selection

International websites

Europe

Americas / Oceania

Africa and Middle East

Asia / Pacific

Etabloc SYT Dry-installed pump

Dry-installed pump Etabloc SYT

Volute casing pump for horizontal or vertical installation, back pull-out design, single-stage, with ratings to EN 733, radially split volute casing, replaceable casing wear rings, volute casing with integrally cast pump feet, closed radial impeller with multiply curved vanes, single mechanical seal to EN 12756, product-lubricated carbon plain bearing, grease-lubricated radial ball bearing in the motor housing, with magnetless KSB SuPremE motor (exception: motor sizes 0.55 kW / 0.75 kW with 1500 rpm are designed with permanent magnets) of efficiency class IE4/IE5 and PumpDrive variable speed system; ATEX-compliant version available.
See all documents and downloads

Main Applications

  • Heat transfer systems
  • Hot water circulation

Technical Data

Maximum flow rate TSG
337 m³/h
Maximum head TSG
99 m
Max allow ds work.pressure TSG
16 bar
Max allowed fluid temp TSG
350 °C

Your KSB contact: We’re here to support you

Do you need any assistance finding the right material number?
We’ll soon provide a list so you can directly place your purchase order.
Meanwhile please contact our support:

Your local contact


Your KSB contact : We’re here to support you

Benefits

  • Designed to deliver reliable operation with mineral and synthetic thermal oils up to 350 °C
  • Maximum operating reliability ensured by KSB mechanical seal with multi-spring arrangement and reliable venting during pump operation
  • Safety barriers: Special contour ensures reliable removal of leakage at the mechanical seal; confined sealing elements and effective heat barrier

Technical Data

Component function
Pump
Connection type Inlet
Flange
Drive concept
With electric actuator
Maximum flow rate TSG
337 m³/h
Minimum flow rate TSG
1 m³/h
Maximum head TSG
99 m
Minimum head TSG
1 m
Mains frequency
50 Hz,
60 Hz
Mains voltage
400 V,
460 V
Nominal pressure Outlet
PN 16
Max allow ds work.pressure TSG
16 bar
Suction behaviour
Non-self-priming
Max allowed fluid temp TSG
350 °C
Min allowed fluid temp TSG
-30 °C

Sectional Drawings