혜택
- Thermosyphon system for use with unpressurised buffer fluid or pressurised barrier fluid (Plans 52 and 53A). A cooling coil is integrated in the system and can be connected as an option. A large range of components can be configured in addition.
- Used for applications where leakage of the fluid handled to atmosphere must be minimised, collected or completely ruled out.
- For double mechanical seals with pressurised barrier fluid or unpressurised buffer fluid. Depending on the application, the pressure of the buffer fluid/barrier fluid is lower/higher than the pressure in the pump’s seal chamber.
기술 데이터
- Cool.power Forced circulat TSG
- 2.5 kW
- Cool.pwr Natural circulat TSG
- 1.2 kW
- Cool.power w/o cool.wtr TSG
- 0.3 kW
- Object type
- Module
- Operat vol Sh sl sup syst TSG
- 1.3 l
- Product type
- Pump shaft s./-s.supply syst.
- Max all.temp Prcss circuit TSG
- 200 °C
- Min all.temp Prcss circuit TSG
- -60 °C
- Max all.op prss Procss circuit
- 16 bar