주 사용 용도
- Untreated sewage
기술 데이터
- Cartridge seal
- Yes
- Design Mechanical seal
- Stationary
- Mechanical seal type
- Balanced mechanical seal
- Sealing type Mechanical seal
- Double
- Max allowed fluid temp TSG
- 100 °C
혜택
- Double mechanical seal in tandem arrangement, can be installed as one unit, bi-directional and balanced.
- Stationary design, springs located outside the fluid handled in the oil reservoir The springs are insensitive to contamination and provide uniform surface pressure across the seal faces, thus ensuring a long service life.
- Tailored to the seal installation space and requirements of the pump.