Benefits
- Thermosyphon system compliant with all requirements of API 682, 4th edition
- For double mechanical seals (Arrangement 3). The barrier fluid pressure is higher than the pressure in the pump’s seal chamber.
- Circulation between the barrier fluid reservoir and the KSB mechanical seal is ensured via a circulation device integrated in the seal. The system and the seal are perfectly matched.
Technical Data
- Object type
- Module
- Working volume
- 4 l,
6.5 l - Product type
- Pump shaft s./-s.supply syst.
- Maximum allowable temperature Cooling circuit
- 200 °C
- Maximum allowable temperature Process circuit
- 200 °C
- Minimum allowable temperature Cooling circuit
- -29 °C
- Minimum allowable temperature Process circuit
- -29 °C
- Maximum allowable operating pressure Cooling circuit
- 16 bar
- Maximum allowable operating pressure Process circuit
- 50 bar