Technical Data

  • Max. flow rate330 m3/h
  • Max. head100 m
  • Max. allowed working pressure10 bar
  • Max. allowed fluid temperature100 °C

Benefits

  • Easy to dismantle due to back pull-out design; no need to remove the pump casing from the piping
  • High operating reliability by mechanical seal in casing cover with conical seal chamber for enhanced circulation and self-venting
  • Long service life through wear-resistant diagonal clearance and impeller with front vanes

Certificates

  • K09A_320572939-1_1
    Certified quality management to ISO 9001
    All countries

Characteristic curves

Your KSB contact: We're here to support you

Do you need any assistance finding the right material number?
We’ll soon provide a list so you can directly place your purchase order.
Meanwhile please contact our support:

Tel: +44 1509 231872


Your KSB contact : We’re here to support you

Documents

TitleFormatSizeLast change
TitleFormatSizeLast change
Performance Curves KWP-Bloc K/O/F (2362.450_090)PDF2.24/19/2021
TitleFormatSizeLast change
TitleFormatSizeLast change
Motor catalog (0902.53_EN)PDF4.284/19/2021
TitleFormatSizeLast change
KSB IE3 Motor; 0,55 - 132 kW (4076.8_EN)PDF1.554/19/2021
KWP-Bloc (2362.8_EN)PDF4.144/19/2021
TitleFormatSizeLast change
Produktvorstellung KWP-Bloc (2362.1_010)pdf0.125/24/2019
TitleFormatSizeLast change
KWP-Bloc (2362.5_EN)PDF4.424/19/2021
TitleFormatSizeLast change
KWP-Bloc (2362.521_EN)PDF0.074/19/2021

Technical Data

  • FunctionPump
  • Connection typeFlange
  • Drive conceptWith electric actuator
  • Max. flow rate330 m3/h
  • Min. flow rate4 m3/h
  • Max. head100 m
  • Min. head2 m
  • Mains frequency50 Hz, 60 Hz
  • Mains voltage400 V, 460 V
  • Casing materialEN-GJL-250, GX3CRNIMOCUN24-6-2-3
  • Nominal pressurePN 10
  • Max. allowed working pressure10 bar
  • Suction behaviourNon-self-priming
  • Max. allowed fluid temperature100 °C
  • Min. allowed fluid temperature-20 °C