Amarex Submersible motor pump
Submersible motor pump

Amarex

Vertical single-stage submersible motor pump for wet installation, with free-flow impeller (F-max) or open dual-vane impeller (D-max), stationary or transportable version. Single-stage, single-entry close-coupled pump sets which are not self-priming. ATEX-compliant version available.
Voir tous les documents et téléchargements

Applications principales

  • Waste water transport
  • Waste water management
  • Drainage systems
  • Waste water treatment plants
Afficher toutes les applicationsicon arrowright

Caractéristiques techniques

  • Max. flow rate330 m³/h
  • Max. head40 m
  • Max. allowed working pressure4 bar
  • Max. allowed fluid temperature40 °C

Avantages

  • High efficiency thanks to enhanced power density (Wh/m3), overall efficiency of up to 69 %, lower total cost of ownership
  • Non-clogging (no clogging by wet wipes) with patented deflection technology and D-max impeller
  • Long service life with high operating reliability and durable bearings (100,000 operating hours)

Courbes caractéristiques

Liste des n° articles – Amarex

5 produits
NomPoidsN° articlePrix
ARX F050-140/023F2USG -15057 Kilogram39110011
ARX F050-140/023F2YSG -15059 Kilogram39110012
ARX F065-170/024F2YSG -14065 Kilogram39110084
ARX F080-150/017F4YSG -16070 Kilogram39110132
ARX F100-230/035F4USG -18092 Kilogram39110263

Documents

TitreFormatTailleDernière modification
icon download-pdfAmarexpdf2.9521/02/2020
TitreFormatTailleDernière modification
icon download-pdfLevelControl Basic 2pdf7.1127/06/2019
icon download-pdfAmarexpdf6.2810/03/2020
TitreFormatTailleDernière modification
icon download-pdfAmarexpdf12.518/06/2020
icon download-pdfAS5pdf1.4304/04/2020
TitreFormatTailleDernière modification
icon download-pdfBrochure Amarexpdf0.6114/03/2020

Caractéristiques techniques

  • FunctionPump
  • Connection typeFlange
  • Drive conceptWith electric actuator
  • Max. flow rate330 m³/h
  • Min. flow rate18.8 m³/h
  • Max. head40 m
  • Min. head1 m
  • Mains frequency50 Hz
  • Mains voltage400 V, 230 V, 690 V, 500 V, 415 V, 380 V
  • Casing material1819
  • Nominal pressurePN 16
  • Max. allowed working pressure4 bar
  • Suction behaviourNon-self-priming
  • Max. allowed fluid temperature40 °C
  • Min. allowed fluid temperature0 °C