Country, region and language selection

International websites

Europe

Americas / Oceania

Africa and Middle East

Asia / Pacific

Magnochem Dry-installed pump

Dry-installed pump Magnochem

Horizontal seal-less volute casing pump in back pull-out design, with magnetic drive, to DIN EN ISO 2858 / ISO 5199, with radial impeller, single-entry, single-stage. ATEX-compliant version available.
See all documents and downloads

Main Applications

  • Chemical industry
  • District heating
  • Industrial recirculation systems
  • Air-conditioning systems

Technical Data

Max. flow rate
1400 m³/h
Max. head
236 m
Max. allowed working pressure
40 bar
Max. allowed fluid temperature
350 °C

Your KSB contact: We’re here to support you

Do you need any assistance finding the right material number?
We’ll soon provide a list so you can directly place your purchase order.
Meanwhile please contact our support:

Tel: +27-11-876-5600


Your KSB contact : We’re here to support you

Benefits

  • High operating reliability:
    • Only static sealing elements are required.
    • Optional leakage barrier

Technical Data

Function
Pump
Connection type
Flange
Drive concept
With electric actuator
Max. flow rate
1400 m³/h
Min. flow rate
1 m³/h
Max. head
236 m
Min. head
3.5 m
Mains frequency
50 Hz,
60 Hz
Mains voltage
400 V,
460 V
Casing material
GP240GH+N/A216 GRADE WCB,
G17CRMOV5-10,
GX5CRNIMO19-11-2/A743 GRADE CF-8M,
GX5CRNIMO19-11-2,
GX3CRNIMOCUN24-6-2-3/GX2CRNIMOCUN25-6-3-3/A9951B
Nominal pressure
PN 40
Max. allowed working pressure
40 bar
Suction behaviour
Non-self-priming
Max. allowed fluid temperature
350 °C
Min. allowed fluid temperature
-90 °C

Sectional Drawings