ECOLINE GLF 800

Globe valve to ANSI/ASME with threaded sockets (NPT), butt weld ends (BW) or socket weld ends (SW), Trim 8 (Stellite/13 % chrome steel), with bolted bonnet, outside screw and yoke, graphite gland packing, stainless steel/graphite gaskets, available in carbon steel and alloy steel.
See all documents and downloads

Main Applications

  • Boiler feed applications
  • Fossil-fuelled power stations
  • Petrochemical industry
  • Pipelines and tank farms
Show all applications

Technical Data

  • Nominal pressureCL 800
  • Max. nominal sizeNPS 2
  • Max. allowed fluid temperature593 °C

Material number list – ECOLINE GLF 800

12 products
Name
Nominal pressure
Nominal size Inlet
Drive concept
Connection type Inlet
API trim number
Weight
Material number
Price
ECOLINE GLF 800 1 1/2 IN SW A105 Trim8CL 800NPS 1 1/2 (DN40)With handwheelWelded/soldered/bonded socket86.2 Kilogram42292957
upon request
ECOLINE GLF 800 1 1/2 IN SW F316 Trim10CL 800NPS 1 1/2 (DN40)With handwheelWelded/soldered/bonded socket106.2 Kilogram42293000
upon request
ECOLINE GLF 800 1 1/4 IN SW A105 Trim8CL 800NPS 1 1/4 (DN32)With handwheelWelded/soldered/bonded socket85.2 Kilogram42292956
upon request
ECOLINE GLF 800 1 1/4 IN SW F316 Trim10CL 800NPS 1 1/4 (DN32)With handwheelWelded/soldered/bonded socket105.2 Kilogram42292999
upon request
ECOLINE GLF 800 1 IN SW A105 Trim8CL 800NPS 1 (DN25)With handwheelWelded/soldered/bonded socket83.7 Kilogram42292955
upon request

Benefits

  • Additional features ensure safe sealing to atmosphere:
    • Serrated bonnet gasket, fully confined to prevent creep.
    • Graphite gland packing with packing end rings (male/female joint)

Technical Data

  • FunctionShut off/control flow
  • Connection typeInternal-thread connection, Butt weld ends, Socket weld ends
  • Design concept DriveWith electric actuator, With handwheel, With pneumatic actuator
  • Casing materialA105, A182 GRADE F 11 CLASS 2, A182 GRADE F 22, A182 GRADE F 304, A182 GRADE F 316
  • Nominal pressureCL 800
  • Max. nominal sizeNPS 2
  • Min. nominal sizeNPS 1/2
  • Max. allowed fluid temperature593 °C
  • Min. allowed fluid temperature0 °C