Comeo Dry-installed pump
Dry-installed pump

Comeo

Multistage, horizontal, close-coupled centrifugal pump
See all documents and downloads

Main Applications

  • Cold water pressure booster system
  • Cold water systems
  • General irrigation systems
  • Light industrial applications

Technical Data

  • Max. flow rate10.8 m³/h
  • Max. head79.5 m
  • Max. allowed working pressure10 bar
  • Max. allowed fluid temperature60 °C

Benefits

  • Top quality pump thanks to advanced high-precision production technology and durable high-grade materials
  • An energy-saving, state-of-the-art pump solution characterised by high efficiency levels, optimum flow passage, the use of high-efficiency motors, and precision engineering of all hydraulic components
  • High energy efficiency as well as low investment and maintenance costs make for low life cycle costs.

Certificates

  • C11A_13688197643-2_2
    -
    United Kingdom
  • C11A_13688197643-1_2
    Approved in accordance with the French drinking water regulation
    France

Characteristic curves

Material number list – Comeo

72 products
NameMin voltage toleranceMotor dimension ONo.of motor starts per hourRated current MotorMotor current typeSound pressure level MotorWeightMaterial numberPrice
Comeo C I002/02-A4B32FS071E5MW10%1 X M18 X 1.5202.6ASingle-phase AC58DB13.1 Kilogram48229175
Comeo C I002/02-A4B32FS071E5OW10%1 X M20 X 1.5201.64AThree-phase current58DB13.1 Kilogram48239960
Comeo C I002/02-A4B32FS071E6MW10%1 X M18 X 1.5202.3ASingle-phase AC64DB13.1 Kilogram48239933
Comeo C I002/02-A4B32FS071E6OW5%1 X M20 X 1.5201.54AThree-phase current58DB13.1 Kilogram48239969
COMEO C I002/04-A4B32FS071E5MW10%1 X M18 X 1.5202.6ASingle-phase AC58DB13.8 Kilogram48229176

Documents

TitleFormatSizeLast change
icon download-pdf2-page product description Comeopdf0.355/24/2019
TitleFormatSizeLast change
icon download-pdfComeopdf2.665/24/2019
TitleFormatSizeLast change
icon download-pdfComeopdf1.375/24/2019

Technical Data

  • FunctionPump
  • Connection typeExternal-thread connection
  • Drive conceptwith electric actuator
  • Max. flow rate10.8 m³/h
  • Min. flow rate0.2 m³/h
  • Max. head79.5 m
  • Min. head15 m
  • Mains frequency50 Hz, 60 Hz
  • Mains voltage230 V, 400 V, 460 V
  • Nominal pressurePN 10
  • Max. allowed working pressure10 bar
  • Suction behaviournon-self-priming
  • Max. allowed fluid temperature60 °C
  • Min. allowed fluid temperature-10 °C

Sectional Drawings