Type Series
(18 results)Amaclean
Self-cleaning tank insert for grouted installation in new concrete structures or in concrete structures in need of refurbishment. Designed to prevent soiling of the structure and clogging of the pumps by heavily waste or fibre loaded waste water. Suitable for pump stations emitting unpleasant odours and/or gases.
AmaDrainer Box/AmaDrainer Box Mini
AmaDrainer Box:Stable above-floor plastic collecting tank or impact-resistant underfloor plastic collecting tank, with floor drain and odour trap, both with AmaDrainer submersible motor pump starting and stopping automatically and swing check valve AmaDrainer Box Mini:Reliable and compact grey water lifting unit in a modern design with activated carbon filter meeting hygiene requirements and with shower connection as standard; complies with EN 12050-2.
CK 800 Pump Station/CK 1000 Pump Station
Single-pump station / dual-pump station as ready-to-connect package system, with PE-LLD (polyethylene) collecting tank for buried installation. Equipped with either one or two submersible waste water pumps of type Amarex N S (explosion-proof or non-explosion-proof) or AmaPorter (non-explosion-proof). Tank design to DIN 1986-100 and EN 752/EN 476.
DeltaBasic
Fully automatic pressure booster system with two to three (MVP) / four (SVP) vertical high-pressure pumps in two variable speed versions. The MVP and SVP variable speed versions ensure variable speed control of each pump by motor-mounted frequency inverter for asynchronous motors (MVP) or by PumpDrive variable speed system and KSB SuPremE motor (SVP), respectively, providing fully electronic control to ensure the required supply pressure. Equipped with a central fuse box.
DeltaMacro
Fully automatic package pressure booster system with two to four (F) / six (VC/SVP) vertical high-pressure pumps; available in cascade-controlled and two variable speed designs. Cascade control (F) for ensuring the required supply pressure. The VC and SVP versions ensure variable speed control of each pump by cabinet-mounted frequency inverter (VC) or motor-mounted PumpDrive variable speed system and KSB SuPremE motor (SVP), respectively, providing fully electronic control to ensure the required supply pressure. Automated with KSB BoosterCommand Pro Plus.
DeltaPrimo
Fully automatic package pressure booster system with two to three (VC) / four (F/SVP) vertical high-pressure pumps; available in cascade-controlled and two variable speed designs. Cascade control (F) for ensuring the required supply pressure. The VC and SVP versions ensure variable speed control of each pump by cabinet-mounted frequency inverter (VC) or motor-mounted PumpDrive variable speed system and KSB SuPremE motor (SVP), respectively, providing fully electronic control to ensure the required supply pressure. Automated with KSB BoosterCommand Pro.
DeltaSolo
Fully automatic single-pump system available in two variable speed versions. The MVP and SVP variable speed versions ensure variable speed control of each pump by motor-mounted frequency inverter for asynchronous motors (MVP) or by PumpDrive variable speed system and KSB SuPremE motor (SVP), respectively, providing fully electronic control to ensure the required supply pressure.
HyaDuo 2 D FL
Fully automatic and ready-to-connect fire-fighting system for fire-fighting applications to DIN 14462:2023-07, modular design, comprising a dual-pump system with redundant function, mounted on the same baseplate. The system is started and stopped as a function of pressure. The system is monitored for lack of water to protect the pumps against dry running. A functional check run is carried out daily to ensure reliable pump operation.
HyaDuo 2 D FL Compact
Compact, fully automatic and ready-to-connect break tank package booster set for fire-fighting applications to DIN 14462:2023-07, modular design, comprising a dual-pump system with redundant function and a break tank for the hygienic separation of drinking water and fire-fighting water, mounted on separable base frames. The system is started and stopped as a function of pressure. The system is monitored for lack of water to protect the pumps against dry running. A functional check run is carried out daily to ensure reliable pump operation.
HyaSolo 2 D FL
Fully-automatic and ready-to-connect single-pump system for fire-fighting applications to DIN 14462:2023-07, in modular design. The system is started and stopped as a function of pressure. The system is monitored for lack of water to protect the pumps against dry running. A functional check run is carried out daily to ensure reliable pump operation.
HyaSolo 2 D FL Compact
Compact, fully automatic and ready-to-connect break tank package booster set for fire-fighting applications to DIN 14462:2023-07, modular design, comprising a single-pump system and a break tank for the hygienic separation of drinking water and fire-fighting water, mounted on the same base frame. The system is started and stopped as a function of pressure. The system is monitored for lack of water to protect the pumps against dry running. A functional check run is carried out daily to ensure reliable pump operation.