KWP Dry-installed pump

Dry-installed pumpKWP

Horizontal radially split volute casing pump in back pull-out design, single-stage, single-entry, available with various impeller types: closed multi-channel impeller, open multi-vane impeller and vortex impeller. ATEX-compliant version available.
See all documents and downloads

Main Applications

  • Paper industry / pulp industry
  • Sugar industry
  • Food industry / beverage industry
  • Fossil-fuelled power stations

Technical Data

  • Max. flow rate15000 m³/h
  • Max. head140 m
  • Max. allowed working pressure10 bar
  • Max. allowed fluid temperature140 °C

Your KSB contact: We’re here to support you

Do you need any assistance finding the right material number?
We’ll soon provide a list so you can directly place your purchase order.
Meanwhile please contact our support:

Your local contact


Your KSB contact : We’re here to support you

Benefits

  • Easy to service thanks to back pull-out design
  • Safe design: all pressure-retaining components cast with extra corrosion/wear allowance.
  • Standard pump with suction-side wear plate in wear-resistant diagonal gap design

Certificates

  • K07A_320572939-1_1
    Certified quality management to ISO 9001
    All countries

Technical Data

  • FunctionPump
  • Connection typeFlange
  • Drive conceptWith electric actuator
  • Max. flow rate15000 m³/h
  • Min. flow rate4 m³/h
  • Max. head140 m
  • Min. head1 m
  • Mains frequency50 Hz,
    60 Hz
  • Mains voltage400 V,
    460 V,
    1000 V
  • Casing materialEN-GJL-250,
    G-X250CRMO 15 3,
    GX3CRNIMOCUN24-6-2-3,
    GX3CRNIMOCUN24-6-5,
    EN-GJS-400-18-LT-CERAMIC POLYSIC
  • Nominal pressurePN 10,
    PN 16
  • Max. allowed working pressure10 bar
  • Suction behaviourNon-self-priming
  • Max. allowed fluid temperature140 °C
  • Min. allowed fluid temperature-40 °C

Characteristic curves

Sectional Drawings

  • Download
  • Download
  • Download
  • Download
  • Download
  • Download
  • Download
  • Download

Documents

Title
Format
Size
Last change
KWPK 60 Hz (2361.460_EN)PDF12.5512/10/2021
KWPK 50 Hz (2361.450_EN)PDF11.6712/10/2021
KWP O-, F-, R-Impeller 50 Hz (2361.454_EN)PDF5.5312/10/2021
Title
Format
Size
Last change
KWP (2361.5_EN)PDF5.878/23/2022