Main Applications

  • Spray irrigation systems
  • Service water supply systems
  • Drainage
  • Drainage systems
Show all applicationsicon arrowright

Technical Data

  • Max. flow rate180 m³/h
  • Max. head105 m
  • Max. allowed working pressure16 bar
  • Max. allowed fluid temperature90 °C

Benefits

  • Maintenance-free mechanical seal ensures operating reliability
  • Easy to dismantle due to back pull-out design; no need to remove the pump casing from the piping
  • Good suction performance, self-priming up to 9 m suction lift, also suitable for applications with relatively poor inlet conditions (i.e. low or negative inlet pressure) and for handling fluids with entrained gas.

Certificates

  • E25B_320572939-1_1
    Certified quality management to ISO 9001
    All countries

Characteristic curves

  • icon downloadDownload
  • icon downloadDownload
  • icon downloadDownload
  • icon downloadDownload

Your KSB contact: We're here to support you

Do you need any assistance finding the right material number?
We’ll soon provide a list so you can directly place your purchase order.
Meanwhile please contact our support:

Tel: +435 91030 0


Your KSB contact : We’re here to support you

Documents

TitleFormatSizeLast change
TitleFormatSizeLast change
icon download-pdfEtaprime Lpdf4.185/24/2019
icon download-pdfEtaprime Lpdf1.935/24/2019

Technical Data

  • FunctionPump
  • Connection typeFlange
  • Drive conceptWith electric actuator
  • Max. flow rate180 m³/h
  • Min. flow rate4 m³/h
  • Max. head105 m
  • Min. head5 m
  • Mains frequency50 Hz, 60 Hz
  • Mains voltage230 V, 400 V, 460 V
  • Casing material1819, 2716
  • Nominal pressurePN 16
  • Max. allowed working pressure16 bar
  • Suction behaviourSelf-priming
  • Max. allowed fluid temperature90 °C
  • Min. allowed fluid temperature-30 °C