Self-priming pumps: the solution to challenging inlet conditions
In many industrial processes, reliable fluid handling is crucial to system availability, product quality and cost-effectiveness. This becomes particularly challenging when pumps cannot be installed below the liquid level or when inlet conditions are unfavourable. It is in cases like these that self-priming pumps show their strengths, enabling reliable pumping operation even in situations where conventional centrifugal pumps reach their limits.
In many industrial processes, reliable fluid handling is crucial to system availability, product quality and cost-effectiveness. This becomes particularly challenging when pumps cannot be installed below the liquid level or when inlet conditions are unfavourable. It is in cases like these that self-priming pumps show their strengths, enabling reliable pumping operation even in situations where conventional centrifugal pumps reach their limits.
Typical applications include washing systems, surface treatment systems, paint shops, water treatment plants and numerous production processes in general industry. The key feature of self-priming pumps is that they can remove air from the suction line and then pump the liquid, which simplifies system designs and improves operating reliability.
Why priming is often a challenge
Conventional centrifugal pumps generally require the suction line to be completely filled with liquid. If there is air in the system, the pump cannot start reliably, which is why additional components such as foot valves, venting devices or complex installations are often used.
In practice, however, consultants are often faced with rather different conditions. Tanks are located below the pump, fluid tanks are regularly emptied or the available installation space does not allow for an optimal arrangement of the pump sets. Fluctuating fill levels also make operation more difficult. In such cases, self-priming pump technology offers an interesting alternative.
How the self-priming process works
The functional principle is based on the targeted separation of air and liquid within the pump casing.
Before commissioning, the operator primes the pump with the fluid to be handled.
After start-up, the impeller creates a vacuum in the vicinity of the impeller inlet. As a result, air initially flows from the suction line into the pump.
Inside the pump casing, the air which is drawn in mixes with the liquid which is already present. The special casing design then separates the two media from one another. While the air is evacuated via the discharge side, the liquid is returned to the pumping circuit. This process keeps repeating continuously. Gradually, the air is evacuated from the suction line until only liquid is being pumped (Figure 4). The pump then operates like a conventional centrifugal pump at its normal operating point.
The self-priming process enables the fluid handled to be transported by first evacuating air and then by drawing in the liquid. Thanks to their special design, self-priming pumps can achieve high suction lifts and reliably handle applications with low inlet pressure or unfavourable inlet conditions.
High suction lifts extend the range of applications
A key advantage of self-priming pumps is their ability to overcome significant vertical distances between the pump and the liquid level. Depending on the size and variant, suction lifts of up to around eight or nine metres are possible. The actual suction lift depends on factors such as pump type, speed, fluid properties and piping losses.
For engineering contractors, this opens up greater structural design flexibility. The pump can be installed above a tank, which makes maintenance work easier and ensures that the components remain more easily accessible. At the same time, in many cases, this reduces the extent of structural measures required.
Benefits in daily industrial operations
Self-priming pumps are not only impressive because of their self-priming capabilities. Many industrial applications benefit from the fact that the pump sets can tolerate temporary air contents in the fluid handled, which improves operating reliability under fluctuating process conditions.
Furthermore, maintenance work is often easier to carry out. In modern designs, such as the Etaprime, inspection covers or back-pull-out designs allow access to key components without having to dismantle the entire piping. This ensures that the pumps remain easy to manage, even in demanding production environments.
For operators, three characteristics are of primary importance:
- Robustness: The technology proves its worth even under difficult installation conditions.
- Ease of operation: After initial priming, the pumping process starts automatically.
- Reliability: The pumps continue to operate reliably even if air enters the suction line or low inlet pressures occur.

Washing systems and cleaning processes
Industrial washing systems are a particularly suitable application. Here, cleaning liquids often need to be pumped from tanks in which the liquid level is below the installed pump. At the same time, fill levels and operating conditions fluctuate regularly.
Self-priming pumps ensure reliable operation without the need for complicated additional equipment. The pump sets can be installed above the tanks, ensuring they remain easily accessible. In component cleaning systems, they support the continuous circulation of cleaning agents and help to ensure high system availability. Numerous examples from practice demonstrate the successful use of self-priming pumps in washing and degreasing systems for industrial components.
Surface treatment and paint shops
Unfavourable inlet conditions are also frequently found in surface treatment systems and paint shops. Process fluids are contained in reservoirs or tanks, while the space available for pump systems is limited.
Self-priming pumps solve this problem thanks to their flexible installation. The pump sets can be installed directly on process tanks or in their immediate vicinity. This offers a significant advantage, particularly in compact system designs. At the same time, easy access is ensured for maintenance and inspection.
In the case of paint shops, there is the additional factor that pumps often have to handle fluids containing certain contaminants or process residues. The Etaprime type series offers hydraulic system designs tailored to this application and suitable material variants.
Handling contaminated fluids
Historically, self-priming centrifugal pumps were often considered to be sensitive to abrasive particles or higher levels of solids. However, the latest generation of Etaprime pumps shows that design modifications have significantly improved their suitability for certain contaminated fluids.
The design of the seal chamber plays a particularly important role here. Optimised flow conditions help to keep solids away from sensitive sealing elements. At the same time, semi-open impellers facilitate the pumping of slightly contaminated fluids. Suitability in practice depends on particle size, solids concentration and the properties of the fluid handled.
Conclusion
Self-priming pumps have become established as an effective solution for applications with challenging inlet conditions. Their particular advantage lies in the suction process, in which air is evacuated first before drawing in the liquid. This means they operate reliably even with high suction lift and low inlet pressure.
Particularly in washing systems, surface treatment systems, paint shops, water treatment systems and many other industrial applications, they offer structural design flexibility and improve operating reliability. In situations where a lack of space, fluctuating fill levels or unfavourable inlet conditions make it difficult to use conventional pump technology, self-priming pumps offer a robust, straightforward and reliable alternative.
Suitable products
Etaprime B
Horizontal self-priming volute casing pump, single-stage, with open multi-vane impeller, close-coupled; pump shaft and motor shaft rigidly connected; ATEX-compliant version available.
Etaprime L
Horizontal self-priming volute casing pump, single-stage, with open multi-vane impeller, from size 40-40-140 with bearing bracket, in back pull-out design, ATEX-compliant version available.