Etanorm-R Dry-installed pump
Dry-installed pump

Etanorm-R

Horizontal long-coupled, single-stage (two-stage for pump size 125-500) volute casing pump in back pull-out design, with replaceable shaft sleeves / shaft protecting sleeves and casing wear rings, with magnetless KSB SuPremE motor of efficiency class IE4/IE5 and PumpDrive variable speed system; ATEX-compliant version available.
See all documents and downloads

Main Applications

  • Water supply systems
  • Spray irrigation systems
  • Drainage systems
  • Air-conditioning systems
Show all applicationsicon arrowright

Technical Data

  • Max. flow rate2280 m³/h
  • Max. head101 m
  • Max. allowed working pressure16 bar
  • Max. allowed fluid temperature140 °C

Benefits

  • Operating costs reduced by trimming the nominal impeller diameter to match the specified duty point
  • Little wear, low vibration levels and excellent smooth running characteristics thanks to good suction performance and virtually cavitation-free operation across a wide operating range
  • Pioneering energy efficiency by variable speed operation in combination with PumpDrive. When used in combination with the KSB SuPremE motor , the pump achieves efficiency level IE4 to IEC/CD 60034-30 Ed. 2 already today.

Certificates

  • E06A_320572939-1_1
    Certified quality management to ISO 9001
    All countries

Characteristic curves

Your KSB contact: We're here to support you

Do you need any assistance finding the right material number?
We’ll soon provide a list so you can directly place your purchase order.
Meanwhile please contact our support:

Tel: + 46 31 7202495

Your KSB contact : We’re here to support you

Documents

TitleFormatSizeLast change
icon download-pdfEtanorm-RXpdf2.415/24/2019
icon download-pdfEtanorm-Rpdf4.565/24/2019
TitleFormatSizeLast change
icon download-pdfEtanorm-Rpdf6.375/24/2019

Technical Data

  • FunctionPump
  • Connection typeFlange
  • Drive conceptWith electric actuator
  • Max. flow rate2280 m³/h
  • Min. flow rate1.5 m³/h
  • Max. head101 m
  • Min. head2 m
  • Mains frequency50 Hz, 60 Hz
  • Mains voltage400 V, 460 V
  • Casing material1819, 8136
  • Nominal pressurePN 16
  • Max. allowed working pressure16 bar
  • Suction behaviourNon-self-priming
  • Max. allowed fluid temperature140 °C
  • Min. allowed fluid temperature-30 °C

Sectional Drawings

  • icon downloadDownload