Movitec Ring-section pump

Ring-section pumpMovitec

Multistage vertical high-pressure centrifugal pump in ring-section design with suction and discharge nozzles of identical nominal diameters arranged opposite to each other (in-line design), close-coupled. With KSB SuPremE, a magnetless synchronous reluctance motor (exception: motor sizes 0.55 kW / 0.75 kW with 1500 rpm are designed with permanent magnets) of efficiency class IE4/IE5 to IEC TS 60034-30-2:2016, for operation on a KSB PumpDrive 2 or KSB PumpDrive 2 Eco variable speed system without rotor position sensors. Motor mounting points in accordance with EN 50347, envelope dimensions in accordance with DIN V 42673 (07-2011). ATEX-compliant version available.
See all documents and downloads

Main Applications

  • Spray irrigation systems
  • General irrigation systems
  • Washing plants
  • Fire-fighting systems

Technical Data

  • Max. flow rate192 m³/h
  • Max. head415 m
  • Max. allowed working pressure40 bar
  • Max. allowed fluid temperature140 °C

Your KSB contact: We’re here to support you

Do you need any assistance finding the right material number?
We’ll soon provide a list so you can directly place your purchase order.
Meanwhile please contact our support:

Your KSB contact : We’re here to support you

Benefits

  • Reliable: product-lubricated plain bearings made of tungsten carbide, cast pump foot, torsion-resistant pump shroud and confined O-rings
  • Long service life: corrosion-resistant hydraulic components made of stainless steel
  • Easy to service: can be fitted with any standardised mechanical seal (to EN 12756)

Certificates

  • M12A_13688197643-1_1
    Approved in accordance with the French drinking water regulation
    France
  • M12A_13688197643-2_1
    Approved in accordance with the UK drinking water regulation
    United Kingdom

Technical Data

  • FunctionPump
  • Connection typeFlange
  • Drive conceptWith electric actuator
  • Max. flow rate192 m³/h
  • Min. flow rate0.2 m³/h
  • Max. head415 m
  • Min. head4 m
  • Mains frequency50 Hz,
    60 Hz
  • Mains voltage230 V,
    400 V,
    460 V
  • Nominal pressurePN 40
  • Max. allowed working pressure40 bar
  • Suction behaviourNon-self-priming
  • Max. allowed fluid temperature140 °C
  • Min. allowed fluid temperature-20 °C

Characteristic curves

Sectional Drawings

  • Download
  • Download
  • Download
  • Download
  • Download
  • Download

Documents

Title
Format
Size
Last change
2-page product description Movitec (1798.026_EN)PDF0.953/3/2023
Title
Format
Size
Last change
Hygiene Certificate (1798.8510-1_EN)PDF0.098/23/2022
Title
Format
Size
Last change
Movitec (ATEX), CE (1798.83_EN)PDF12.682/24/2023
Movitec (1798.82_EN)PDF12.231/13/2023
Title
Format
Size
Last change
PumpDrive 2/ PumpDrive 2 Eco (4074.5_EN)PDF12.828/23/2022
Movitec; 50 Hz (1798.52_EN)PDF14.0211/26/2021
Movitec; 60 Hz (1798.561_US)PDF13.3411/17/2021