Etaline L Dry-installed pump
Dry-installed pump

Etaline L

Single-stage close-coupled in-line volute casing pump, with PumpDrive variable speed system and common motor/pump shaft
See all documents and downloads

Main Applications

  • Service water supply systems
  • Heating systems
  • Industrial recirculation systems
  • Air-conditioning systems
Show all applicationsicon arrowright

Technical Data

  • Max. flow rate95 m³/h
  • Max. head21 m
  • Max. allowed working pressure10 bar
  • Max. allowed fluid temperature120 °C

Benefits

  • Improved efficiency and NPSHreq by experimentally verified hydraulic design of impellers (vanes)
  • Little wear, low vibration levels and excellent smooth running characteristics thanks to good suction performance and virtually cavitation-free operation across a wide operating range
  • Casing sealed reliably – even in varying operating conditions – by confined casing gasket

Characteristic curves

Material number list – Etaline L

1 product
NameMains voltageMotor current typeNominal diameter impellerEfficiency classPump speedMotor rated currentWeightMaterial numberPrice
ETLL 040-040-100 BBPAV11D201102C A18.9 Kilogram48270252

Documents

TitleFormatSizeLast change
icon download-pdfEtaline L (1514.8_EN)pdf4.394/29/2020
icon download-pdfEtaline L; 60 Hz (1514.86_US)pdf2.075/24/2019

Technical Data

  • FunctionPump
  • Connection typeFlange
  • Drive conceptWith electric actuator
  • Max. flow rate95 m³/h
  • Min. flow rate1 m³/h
  • Max. head21 m
  • Min. head2 m
  • Mains frequency50 Hz
  • Mains voltage230 V, 400 V
  • Nominal pressurePN 10
  • Max. allowed working pressure10 bar
  • Suction behaviourNon-self-priming
  • Max. allowed fluid temperature120 °C
  • Min. allowed fluid temperature-10 °C

Sectional Drawings

Your KSB contact : We’re here to support you