HPK Dry-installed pump

Dry-installed pump HPK

Horizontal radially split volute casing pump in back pull-out design, with radial impeller, single-entry, single-stage, to ISO 2858 / ISO 5199. Optional TRD type testing by TÜV. ATEX-compliant version available.
모든 문서와 다운로드 보기

주 사용 용도

  • Pump for handling hot water and organic or synthetic heat transfer fluids in piping or tank systems.
  • Heating systems
  • Forced circulation boilers
  • District heating

기술 데이터

Maximum flow rate TSG
4800 m3/h
Maximum head TSG
275 m
Max allow ds work.pressure TSG
40 bar
Max allowed fluid temp TSG
240 °C

KSB 연락처: 항상 고객을 지원합니다.

올바른 제품 번호를 찾는 데 도움이 필요하십니까?
직접 주문이 가능하도록 빠른 시일 내에 컨텐츠를 제공할 예정입니다.
그동안 저희 지원팀에 문의해 주시기 바랍니다.

Your KSB contact : We’re here to support you

혜택

  • Hydraulic system, nominal data and dimensions to ISO 2858 / EN 22858
  • Continuous lubrication and oil level monitoring by constant level oiler
  • Back pull-out design allows the casing to remain in the piping while the pump is dismantled.

기술 데이터

Component function
Pump
Connection type Inlet
Flange
Drive concept
With electric actuator
Maximum flow rate TSG
4800 m3/h
Minimum flow rate TSG
1 m3/h
Maximum head TSG
275 m
Minimum head TSG
2 m
Mains frequency
50 Hz,
60 Hz
Mains voltage
400 V,
460 V
Mtrl Hydraulic casing
GX23CRMOV12-1,
EN-GJS-400-18-LT,
GP240GH+N/A216 GRADE WCB
Nominal pressure Outlet
PN 40
Max allow ds work.pressure TSG
40 bar
Suction behaviour
Non-self-priming
Max allowed fluid temp TSG
240 °C
Min allowed fluid temp TSG
5 °C

단면도